4DP10 Pilot Directional Control Valve Dealer in Chennai. Available as spring centered, spring offset. Valve mounting interface conforms to International and National standards.
Download PDF
4DP10 Pilot Directional Control Valve Dealer in Chennai.
Unit Dimensions :
Construction ………………………………………………Spool type.
Mounting …………………………………………………..Subplate mounting as perISO 4401 – AC – 05 -4 – A andIS 10187 – 10 mm diameter nominal port.
Mounting position ……………………………………….Optional.
Flow direction …………………………………………….As per spool type.
Operating pressure ……………………………………..For port P, A and B ….. 350 bar.For port T ……………….. 250 bar.For port X and Y ………… 150 bar.
Minimum pilot pressure ………………………………..5 bar.
Hydraulic medium ……………………………………….Mineral oil.
Viscosity range ……………………………………………10 cSt to 380 cSt.
Fluid temperature range ………………………………-20 °C to +70 °C.
Fluid cleanliness requirement ……………………….As per ISO 16/13 or better.
Maximum flow handling capacity …………………..Refer performance curves.
Mass …………………………………………………………3.5 kg APPROX